ESSER by Honeywell Compact/Single Loop Intelligent Addressable
ESSER by Honeywell Compact/Single Loop Intelligent Addressable
The Compact is a powerful, professional one loop circuit fire alarm control panel for monitoring small to medium-sized premises with increased demands on reliability - redundancy through the ring wiring. It allows simultaneous detection, control, and warning, both on the ring bus including stubs, as well as with the inputs and outputs built into the control panel, e.g. fire brigade interface, interface for fire control, outputs for conventional signal generators, and other relays for individual controls.
The Compact has a short circuit and open circuit tolerant Esserbus-PLus loop bus, on which up to 127 intelligent and individually addressable bus devices are supported.
Commissioning and configuration of customer-specific system data is with proven 8000 programming software tools.
The fire brigade peripherals (FBCP, FAT) or a remote control unit can be operated via the integrated RS485 interface.
Ideal for premises such as schools, kindergartens, nursing homes, doctors' offices, hardware stores, small hotels, shops, small businesses, and manufacturing or retail.
Technical Data
Rated voltage | 230 V AC |
Rated frequency | 50 ... 60 Hz |
Rated current | 0.08 A |
Battery capacity | max. 2 x 12 V/12 Ah |
Ambient temperature | -5 °C ... 45 °C |
Storage temperature | -5 °C ... 50 °C |
Air humidity | < 95 % (non-condensing) |
Type of protection | IP30 |
Housing | ABS, 10 % glass fiber reinforced, V-0 |
Color | Gray, similar to Pantone 538 |
Weight | Approx. 5 kg (without batteries) |
Dimensions | W: 450 mm H: 320 mm D: 185 mm |
Declaration of Performance | DoP-21390140811 |
Features
- Single loop panel (the system supports up to 127 digital loop addresses in total)
- Integrated esserbus®-PLus
- Short circuit and open circuit tolerant loop operation with stub cable exits
- Operation of bus-supplied, synchronously controlled alarm generators (optical/acoustic/ voice) indifferent alarm areas via esserbus-Plus powered loop technology
- Length of the loop circuit (esserbus) up to 3.5km
- Up to 127 esserbus devices (fire detectors or manual call points)/group
- Up to 32 esserbus transponders
- Up to 30 IQ8Quad detectors with integrated signal generators
- Up to 20 IQ8Alarm signal generators
- Operation of ATEX approved detectors (intrinsically safe) for potentially explosive areas
- Optimized commissioning, maintenance, and operation
- Easy configuration and programming of the FACP functions via display
- 4 relays, programmable, not monitored, potential-free, max. 30 V DC/2 A or 60 V DC/1 A
- 2 outputs for connection to acoustic and optical signal generators according to EN 54-13 (each 24 V DC/max. 500 mA)
- 1 interface to a transmission unit (TU) for fire alarm (12 V DC/max. 200 mA)
- 1 interface to a transmission unit (TU) for fault reports (12 V DC/max. 200 mA)
- 1 standard interface solution for fire control type C acc. DIN EN 54-2
- RS485 for connection of fire brigade control panel and fire brigade graphic annunciator
- 1 output UBext 24 V/0.5 A, for the voltage supply of external devices, 72-hour emergency bypass (depending on configuration)
- Integrated detector groups individual display
- Function "delay the transmission" (according to DIN VDE 0833-2, to avoid false alarms, delay/ investigate)
- Function "two-message dependency" (according to DIN VDE 0833-2, to avoid false alarms), alternatively programmable as alarm caching, multi-group dependence, or multi-detector dependency
- Operating panel with alphanumerical display
- Large LCD display with 8 rows x 40 characters
- Alarm counter for up to 10,000 trips
- Event memory for up to 10,000 events
ESSER by Honeywell Compact/Single Loop Intelligent Addressable
The Compact is a powerful, professional one loop circuit fire alarm control panel for monitoring small to medium-sized premises with increased demands on reliability - redundancy through the ring wiring. It allows simultaneous detection, control, and warning, both on the ring bus including stubs, as well as with the inputs and outputs built into the control panel, e.g. fire brigade interface, interface for fire control, outputs for conventional signal generators, and other relays for individual controls.
The Compact has a short circuit and open circuit tolerant Esserbus-PLus loop bus, on which up to 127 intelligent and individually addressable bus devices are supported.
Commissioning and configuration of customer-specific system data is with proven 8000 programming software tools.
The fire brigade peripherals (FBCP, FAT) or a remote control unit can be operated via the integrated RS485 interface.
Ideal for premises such as schools, kindergartens, nursing homes, doctors' offices, hardware stores, small hotels, shops, small businesses, and manufacturing or retail.
Technical Data
Rated voltage | 230 V AC |
Rated frequency | 50 ... 60 Hz |
Rated current | 0.08 A |
Battery capacity | max. 2 x 12 V/12 Ah |
Ambient temperature | -5 °C ... 45 °C |
Storage temperature | -5 °C ... 50 °C |
Air humidity | < 95 % (non-condensing) |
Type of protection | IP30 |
Housing | ABS, 10 % glass fiber reinforced, V-0 |
Color | Gray, similar to Pantone 538 |
Weight | Approx. 5 kg (without batteries) |
Dimensions | W: 450 mm H: 320 mm D: 185 mm |
Declaration of Performance | DoP-21390140811 |
Features
- Single loop panel (the system supports up to 127 digital loop addresses in total)
- Integrated esserbus®-PLus
- Short circuit and open circuit tolerant loop operation with stub cable exits
- Operation of bus-supplied, synchronously controlled alarm generators (optical/acoustic/ voice) indifferent alarm areas via esserbus-Plus powered loop technology
- Length of the loop circuit (esserbus) up to 3.5km
- Up to 127 esserbus devices (fire detectors or manual call points)/group
- Up to 32 esserbus transponders
- Up to 30 IQ8Quad detectors with integrated signal generators
- Up to 20 IQ8Alarm signal generators
- Operation of ATEX approved detectors (intrinsically safe) for potentially explosive areas
- Optimized commissioning, maintenance, and operation
- Easy configuration and programming of the FACP functions via display
- 4 relays, programmable, not monitored, potential-free, max. 30 V DC/2 A or 60 V DC/1 A
- 2 outputs for connection to acoustic and optical signal generators according to EN 54-13 (each 24 V DC/max. 500 mA)
- 1 interface to a transmission unit (TU) for fire alarm (12 V DC/max. 200 mA)
- 1 interface to a transmission unit (TU) for fault reports (12 V DC/max. 200 mA)
- 1 standard interface solution for fire control type C acc. DIN EN 54-2
- RS485 for connection of fire brigade control panel and fire brigade graphic annunciator
- 1 output UBext 24 V/0.5 A, for the voltage supply of external devices, 72-hour emergency bypass (depending on configuration)
- Integrated detector groups individual display
- Function "delay the transmission" (according to DIN VDE 0833-2, to avoid false alarms, delay/ investigate)
- Function "two-message dependency" (according to DIN VDE 0833-2, to avoid false alarms), alternatively programmable as alarm caching, multi-group dependence, or multi-detector dependency
- Operating panel with alphanumerical display
- Large LCD display with 8 rows x 40 characters
- Alarm counter for up to 10,000 trips
- Event memory for up to 10,000 events